The pressure switch is a small but indispensable assembly of a large and small pumping station. And if all the rest of its elements just need to be connected correctly, then it will also have to be additionally configured. It is this device that is responsible for automating the pumping process. It turns on and off the equipment according to the pressure readings in the hydraulic tank.
Properly performed adjustment of the pressure switch for the pump is the key to comfort and long service life of the equipment. We describe in detail how it is performed, what actions need to be performed, and what data to know for fine-tuning. You will find out why and in what situation it is being produced.
In addition to a step-by-step description of the adjustment procedure, we provide valuable recommendations reported by hydraulic engineers. To optimize perception, the text is supplemented with photo selections, diagrams, video guides.
Features of the device and principle of operation
Numerous varieties of pressure switches, which are equipped with almost all pumping stations, are arranged approximately the same.
Inside the plastic case there is a metal base on which the remaining elements are fixed:
- membrane;
- piston;
- metal platform;
- node electrical contacts.
Above, under the plastic cover, there are two springs - large and small. When the membrane is under pressure, it pushes the piston.
He, in turn, raises the platform, which acts on a large spring, compressing it. The large spring resists this pressure, restricting the movement of the piston.
The small distance that separates the large and small adjustment springs is enough to regulate the operation of a whole range of devices. The platform under pressure from the membrane gradually rises until its edge reaches a small spring. The pressure on the platform at this moment increases, as a result, its position changes.
Image Gallery
Photo from
Standard installation location for pressure switch
The principle of the device and the specifics of the pressure switch
Pressure switch in automation kit format
Using a pressure switch in a water system
Dismantling the pressure switch for corrections
Conditions for repair obligations
Pressure switch adjustment for water supply
Pressure Switch Adjustment
This causes the contacts to switch, which changes the pump operating mode, and it turns off. To switch contacts there is a special hinge with a spring.
When the platform overcomes the level at which this hinge is located, the electrical contacts change position, opening the power supply circuit. At this point, the pump shuts off. After that, the water stops flowing and the pressure exerted on the membrane decreases as water is consumed from the accumulator.
Accordingly, the platform descends smoothly. When its position is lower than the spring hinge of the electrical contacts, they rise, again turning on the power.
The pressure switch is a small device that allows you to turn the pump on and off depending on the presence or absence of water in the hydraulic accumulator
The pump pumps water into the hydraulic tank, the relay membrane presses on the platform, it rises, reaches a large spring, etc. The cycle resumes and is performed automatically.
Using a large spring, a pressure indicator is set at which the pump unit must be turned on, and a small one determines not the “ceiling” of the permissible pressure in the system, as you might think, but the difference between these two indicators. This is an important point that will come in handy when studying the procedure for setting up the pressure switch of your own pump.
Is there any need for tuning?
Of course, independently or with the help of a specialist, but everyone who assembled their pumping station from separate elements will need to set up a pressure switch.
There is an opinion that ready-made pumping stations, bought in assembled form, are equipped with a pressure switch already configured and prepared for operation. In practice, this is far from always the case.
Before connecting and adjusting the pressure switch, carefully study the technical documentation provided by the manufacturer to find out the maximum permissible pressure values
Each water system has individual characteristics. And the needs of the residents of the house can be different.
The constant pressure in the home system, in which there is only a shower, kitchen sink and bathtub, differs significantly from the needs of a spacious cottage with a jacuzzi and a hydromassage. Factory settings do not always correspond to the real state of affairs.
Pumping stations are usually already equipped with a pressure switch, but still after connecting it will have to be configured for the needs of a particular water system
In addition to adjusting the pressure switch when installing the pumping station, it is also necessary to periodically check and adjust its operation.
The same operation will have to be repeated if some part of the pumping station is out of order, has been repaired or replaced. The procedure for adjusting equipment is practically no different from the procedure for setting it up.
General terminology of indicators
When setting up the pressure switch, some specific names are used. They are well understood by a specialist, but a beginner can be confused. It is better to immediately understand their essence, so as not to get confused during the performance of work.
These terms are:
- inclusion pressure;
- shutdown pressure;
- pressure drop;
- maximum shutdown pressure.
Off pressure is usually referred to as Poff. Sometimes this indicator is also called upper pressure. This indicator, as the name implies, indicates the pressure at which the pump starts or resumes operation, and water begins to pump into the hydraulic tank. Typically, the manufacturer defaults to a lower pressure of 1.5 bar.
Turn-on pressure, by analogy, is also called lower pressure and is designated as Rvcl. This is the second granite indicator, on the relay coming from the factory, usually set to about 3 bar or slightly less.
The differential pressure or delta (ΔP) is calculated as the difference between the lower and upper pressure. In the standard model of a pressure switch, this value is usually around 1.5 bar before adjustment.
The maximum, or rather the maximum allowable, shutdown pressure allows you to get an idea of the maximum pressure in the system. Exceeding this indicator can cause significant harm to water supply and equipment. Typically, this is about 5 bar or slightly less.
Pressure accumulator
Understanding how the accumulator is arranged will help to better cope with self-tuning of control equipment.
There are two types of hydraulic tanks: with a rubber insert reminiscent of sadness, or with a rubber membrane. This element divides the container into two non-communicating parts, one of which contains water and the other contains air.
Inside the tank is a rubber pear-shaped insert or rubber membrane. The pressure in the hydraulic tank can be adjusted by pumping or bleeding air
In any case, they work approximately the same. Water enters the tank, and a rubber insert presses on it to allow movement of water through the plumbing system.
Therefore, a certain pressure is always present in the hydraulic tank, which varies markedly depending on the amount of water and air in the tank.
In order to measure the air pressure in the hydraulic tank before setting up the relay, connect the pressure gauge to the nipple connection provided on the device body
The tank body usually has a car nipple.Through it, air can be pumped into the hydraulic tank or vented to adjust the working pressure inside the tank.
When connecting the pressure switch to the pump, it is recommended to measure the current pressure in the hydraulic tank. The manufacturer defaults to 1.5 bar. But in practice, part of the air usually leaves, and the pressure in the tank will be lower.
To measure the pressure in the accumulator, use a conventional car pressure gauge. It is recommended to choose a model with a scale on which the smallest gradation step is affixed. Such a device will allow for more accurate measurements. It makes no sense to measure pressure if it is not possible to take into account one tenth of a bar.
In this regard, it makes sense to check the pressure gauge with which the pumping station of industrial production is equipped.
Often manufacturers save and install inexpensive models. The accuracy of measurements with such an instrument may be in doubt. It is better to replace it with a more reliable and accurate device.
When choosing a manometer for a pump station or a pump with a hydraulic tank, it is worth paying attention to mechanical models with an accurate gradation scale
Mechanical automobile pressure gauges do not look very presentable, however, judging by the reviews, they are much better than newfangled electronic devices. If nevertheless the choice is made in favor of an electronic pressure gauge, you should not save. It is better to take a device manufactured by a reliable manufacturer than a cheap plastic craft that does not provide accurate data and can break at any time.
Another important point - the electronic pressure gauge requires power, this will have to be monitored. Checking the pressure in the tank is very simple.
A pressure gauge is attached to the nipple and the readings are measured. Normal pressure is considered in the range from one to one and a half atmospheres. If the pressure in the tank is too high, the water supply in it will be less, but the pressure will be just fine.
This diagram illustrates how to connect a pressure switch and pressure gauge to a submersible pump and hydraulic tank in order to automate the operation of pumping equipment
Remember that too high a pressure in the system can be dangerous. In this case, all components of the water supply system constantly work under increased load, and this leads to rapid wear of the equipment. In addition, in order to maintain increased pressure in the system, it is necessary to pump water into the tank more often, and therefore more often, turn on the pump.
It is also not very useful, as the likelihood of breakdowns increases. When setting up the system, a certain balance is needed. For example, if the pressure in the accumulator is too high or excessively low, this can damage the rubber gasket.
Image Gallery
Photo from
Automation unit with pressure switch for water supply
Connection point of the union with the pressure switch
Outputs for connecting to a five-way fitting
Pressure gauge in the format of an automation unit with a pressure switch
How to configure the relay?
There is a cover on the pressure switch housing, and under it are two springs equipped with nuts: large and small. Rotating these springs, set the lower pressure in the accumulator, as well as the difference between the values of the on and off pressure. The lower pressure is regulated by a large spring, and a small one is responsible for the difference between the upper and lower pressure.
Under the cover of the pressure switch are two adjustment springs. A large spring controls the activation of the pump, and a small spring - the difference between the on and off pressure
Before starting the setup, it is necessary to study the technical documentation of the pressure switch, as well as the pump station: hydraulic tank and its other elements.
The documentation indicates the operating and limit indicators for which this equipment is designed.During the adjustment, these indicators should be taken into account so as not to exceed them, otherwise these devices may soon break down.
Sometimes it happens that during the adjustment of the pressure switch, the pressure in the system still reaches the limit values. If this happens, you just need to turn off the pump manually and continue tuning. Fortunately, such situations are extremely rare, since the capacity of household surface pumps is simply not enough to bring the hydraulic tank or system to the limit.
On the metal platform where the adjustment springs are located, the designations “+” and “-“ are made, which allow you to understand how to rotate the spring to increase or decrease the indicator
It is useless to set up the relay if the accumulator is filled with water. In this case, not only the water pressure will be taken into account, but also the air pressure in the tank.
To adjust the pressure switch, the following steps must be performed:
- Set the working air pressure in the empty accumulator.
- Turn on the pump.
- Fill the tank with water until a lower pressure is reached.
- Turn off the pump.
- Turn the small nut until the pump starts.
- Wait until the tank is full and the pump shuts off.
- Open water.
- Turn the large spring to set the switching pressure.
- Turn on the pump.
- Fill the tank with water.
- Correct the position of the small adjustment spring.
You can determine the direction of rotation of the adjustment springs by the signs “+” and “-”, which are usually nearby. To increase the switching pressure, the large spring should be rotated clockwise, and to reduce this figure, it is rotated counterclockwise.
The control springs of the pressure switch are very sensitive, so they need to be tightened very carefully, constantly checking the condition of the system and the pressure gauge
The rotation of the adjustment springs during the adjustment of the pressure switch for the pump must be performed very smoothly, about a quarter or half revolution, these are very sensitive elements. The pressure gauge, when turned on again, should indicate a lower pressure.
With regard to indicators when adjusting the relay, it will be useful to remember the following points:
- If the hydraulic tank is filled, and the pressure gauge remains unchanged, then the limit pressure in the tank has been reached, the pump should be immediately turned off.
- If the difference between the turn-off and turn-on pressures is about 1-2 atm., This is considered normal.
- If the difference is greater or less, repeat the adjustment taking into account possible errors.
- The optimal difference between the set lower pressure and the pressure determined at the very beginning in the empty accumulator is 0.1-0.3 atm.
- In the accumulator, the air pressure should not be less than 0.8 atm.
The system can regularly turn on and off in automatic mode and at other indicators. But these boundaries make it possible to minimize the wear of equipment, for example, the rubber tab of the hydraulic tank, and to extend the operating time of all devices.
Some tips and tricks
For the normal functioning of the pumping station, it is recommended to measure the air pressure in the hydraulic accumulator every three months. This measure will help maintain stable settings in the operation of the equipment. A sharp change in indicators may indicate some breakdowns that need to be addressed.
In order to quickly monitor the state of the system, it makes sense just from time to time to record the readings of the water manometer when turning on and off the pump. If they correspond to the numbers set during the equipment setup, the system operation can be considered normal.
A noticeable difference indicates that you need to check the air pressure in the tank and, possibly, reconfigure the pressure switch.Sometimes you just need to pump a little air into the accumulator, and the indicators will return to normal.
The accuracy of the pressure gauge has a certain error. In part, this can be caused by the friction of its moving parts during measurements. To improve the reading process, it is recommended that the manometer be additionally lubricated before starting the measurement.
The pressure switch, like other mechanisms, tends to wear out over time. Initially, you should choose a durable product. An important factor in the continued operation of the pressure switch is the correct settings. Do not use this instrument at the maximum permissible upper pressure values.
If there are problems and inaccuracies in the operation of the pressure switch, it may be necessary to disassemble and clean it from contamination.
A small margin should be left, then the elements of the device will not wear out so quickly. If it is necessary to set the upper pressure in the system at a sufficiently high level, for example, five atmospheres, it is better to purchase a relay with a maximum permissible work value of six atmospheres. To find such a model is more difficult, but it is quite possible.
Serious damage to the pressure switch can result from contamination in the water pipes. This is a typical situation for old water pipes made of metal structures.
Before installing the pumping station, it is recommended to thoroughly clean the water supply. A complete replacement of metal pipes with plastic structures, if possible, will not hurt.
When adjusting the relays, the adjustment springs should be treated with extreme care. If they are compressed too much, i.e. twisted during the setup process, when the device is working, errors will very soon become apparent. Damage to the relay in the near future is almost guaranteed.
If during checking the operation of the pumping station there is a gradual increase in the shutdown pressure, this may indicate that the device is clogged. No need to change it right away.
It is necessary to unscrew the four mounting bolts on the pressure switch housing, remove the membrane assembly and thoroughly flush the inside of the relay, where possible, as well as all small holes.
Sometimes it’s enough just to remove the relay and clean its holes from the outside without disassembling. It also does not hurt to clean the entire pumping station. If water suddenly begins to flow directly from the relay case, then particles of pollution have pierced the membrane. In this case, the device will have to be completely replaced.
An overview of the pressure switch device is presented here:
This video footage details the process of setting up a pressure switch:
Setting up a pressure switch is not always easy. It is necessary to act carefully and carefully. But an understanding of the principles of the device and the features of its settings allows us to cope with this task quite satisfactorily.
We are waiting for your stories about the experience of installing and configuring a pressure switch, operating a pump system equipped with a device. Perhaps you had questions in the process of getting acquainted with the material? Ask them and comment on the article in the block below.