It is likely that you have encountered state control of gas appliances. Perhaps you are an entrepreneur, and even the most insignificant aspects related to expenses matter to you? We believe that a very small number of people know the rules of calibration of gas analyzers, and meanwhile, an unsuccessfully selected device will cost tens of thousands of rubles overpayment.
We tried to collect all the useful information together. We are talking about all the key points: standards, frequency, stages of verification. You will thoroughly approach the choice of a gas analyzer if you read the material presented by us.
Gas analyzers are subject to state regulation, as they ensure safety at facilities from different fields of human activity. This is primarily true of calibrations that are performed to ensure compliance with metrological characteristics. Let's look at how verification activities are held together.
Features of gas analysis instruments
A gas analyzer is a device for determining the quantitative and qualitative composition of a gas mixture. So says science. Manual absorption analyzers are widely used, in which reagents gradually absorb gas components. Automatic devices in a continuous mode determine the physical and physicochemical values of mixtures and their components.
Gas analyzers are divided into 3 groups. All devices operate on physical methods of analysis, and the difference is expressed in the ability to take into account chemical processes.
Sigma-03 is a stationary multichannel analyzer with separate blocks and modules, including the SIGMA-03 information block. IPC, the set also includes hardy sensors up to 8
Type 1 devices monitor, among other things, related chemical reactions. Analyzers determine changes in the pressure of the fuel mixture and its volume after chemical interaction between the components.
Type 2 gas analyzers provide indicators of physical analysis, which applies to chromatographic, photoionization, electrochemical, thermochemical and other physical and physicochemical processes.
Type 3 devices only work on the principle of physical analysis. The measurement methods they have are magnetic, densimetric, thermoconductometric and optical.
Instruments for the analysis of gas mixtures also classify:
- by appointment;
- by the number of measuring channels;
- by the number of measured components;
- by design;
- by functionality.
It is worth knowing more about devices that differ in the last sign. Gas analyzers perform the functions of conventional measuring instruments, as well as signaling devices, leak detectors, indicators.
Scopes of gas analyzers
Gas meters are used in explosive facilities, boilers of thermal power plants, chemical enterprises, vehicles. Analyzers are also used before firing work in wells and basements.
Explosive gases pose a special threat in a confined and narrow space - that is why gas analyzers are indispensable before fire work in basements and wells.
Devices benefit owners of gas, vacuum and refrigeration equipment: thanks to meters, they determine leaks, leaks, and the concentration of combustible gases. Doctors use gas analyzers to monitor concentrations in the respiratory circuit during painkillers.In the field of environmental protection, these devices have also found useful applications.
Read more about the principle of operation of the gas analyzer in this material.
Calibration of gas analyzers in Russia
Measuring instruments subject to state supervision are inspected for compliance with metrological characteristics. Ordinary citizens and entrepreneurs should be aware that since 2008, activities in this area have been regulated by Federal Law No. 102 “On Ensuring the Uniformity of Measurements”. A gas analyzer or other metering device is checked at a certain frequency, usually once a year.
Preparation for calibration of a gas meter
Verification gas mixtures (ASG) in cylinders can withstand during the day in the room for verification. The gas analyzer itself is stored there for at least 2 hours. At the same time, inspection tools are being prepared, as discussed in the operational documentation.
Based on the documents and the operating instructions for a particular product, they check the analyzer equipment, after which the device is prepared for operation. Preparatory measures are a component of the verification procedure for any type of gas analyzer, in the technical documentation it corresponds to paragraph 5.
Verification gas mixtures are in a wide variety on the market, but only state standard samples (GSO) are used for verification work
The essence of verification is that ASGs are passed through gas analysis equipment at the right speed. When the number of cylinders is more than 1, a multi-way valve is used. The composition is switched by a simple turn of the crane.
Equipment Inspection Sequence
Verification begins with an external inspection, and take into account visible problems and damage. They also look at the clarity of the inscriptions on the front panel, the condition of the thread on the fittings. According to the instructions for a specific gas analyzer, a functional check is carried out.
In the process, the gas mixture will pass through the gearbox and fall into line with the sensor. The test will come to its logical conclusion when the specialist determines the main indicators of metrological characteristics: measurement errors, as well as variations in indicators for different gas contents.
The trusting organization will issue a certificate or leave a stamp on the device. Due to the design features of some gas analyzers, the mark is sometimes put directly on a paper document.
There are 5 types of verification:
- primary;
- periodic;
- extraordinary;
- inspection;
- expert.
The primary implementation before the start of the operation of the analyzer. Also, after repair, the owners will have to repeat the procedure.
Periodic checks are performed as planned. Charts are indicated in the documentation, and metrological services of enterprises make up these schedules. After the plan is approved by Rosstandart, the head of the company will have to approve it.
Private companies are also contacted for verification: the latter meet different questions, and their data can be useful in disputed situations
Extraordinary verification will be necessary in case of loss of a document on inspection of equipment, damage or a long downtime of the device.
Also, gas analyzers are subject to inspection inspection. This means a visit within the framework of state metrological supervision.
If there are disagreements on metrological characteristics, they resort to expert verification. It may be appointed by the prosecutor or the court, but sometimes the desire of the consumer is enough.
Guidelines for the calibration of gas analyzers
Devices should work correctly with radio interference with values within the limits of Norm 1-72-9-72. As for the indicators of the gas analyzers themselves, then not only the flow rate, but also the flow rate instead of it can be subject to rationing if necessary. The main error, in which case, is replaced by random and systematic components.
Metrological standards are established in technical or standard conditions for a specific gas analyzer, depending on the scope of application and indicating the conditions for calibration work in accordance with GOST 8.401-80. Under normal conditions, the difference between the extreme values of the measurements for the permissible basic error is allocated within 25%.
Conditions for work
First of all, they provide security. Only those rooms where there is a supply and exhaust ventilation are suitable for verification. After fulfilling this requirement, the content of harmful substances in the working area of the enterprise is checked, and the norm is specified in GOST 12.1.005.
The owner of the company is responsible for the safety of the verification room, for each type of explosive gas there is a permissible concentration in the air
Employees are protected from electric shock - based on GOST 12.2.007.0 and other requirements from safety regulations. The use of gas mixtures in cylinders is regulated by PB 03-576-03, they are the Rules for the Construction and Safe Operation of Pressure Vessels.
For verification, you will have to comply with such requirements and restrictions:
- voltage of 220 V;
- consumption of ASG at the level of 0.18-0.35 dm³ / min;
- atmospheric pressure not lower than 84 kPa and not higher than 106;
- relative humidity in the range of 30–80%;
- ambient temperature from +15 to +25 ° C.
Verification is carried out only by certified employees on measuring instruments according to PR 50.2.012-94. Before doing their job, they must read the manual for the gas analyzer, and also work with the instruments.
In the process, the specialist will record and enter the following data:
- Document Number;
- Date
- name of the owner of the gas analyzer;
- number of the device to be verified;
- instrument readings and error parameters.
As a result, the owner of the meter will receive a signed certificate with the mark “Suitable”, but if you are not lucky with the quality of the device, then a notice with the record “Not suitable”.
Representatives of the Center for Standardization and Metrology will immediately stop checking if they receive an unsatisfactory result by varying the readings, the main or absolute error, the alarm response time.
The verification act must confirm the suitability of the product, as well as attest compliance with the methodology for a particular gas analyzer, indicating its name and serial number
The fuel metering equipment must have an information unit, a charger and a passport before verification. The same applies to the act of the last verification, if carried out, as well as removable cartridges and remote probes, if any.
What do you need to know about frequency?
Legislators at the state level obliged all organizations that own gas analyzers to provide these devices for verification. The work is carried out by representatives of the State Metrological Service and certified services of private organizations. The frequency indicator for checking the sensor depends on the model of the gas analyzer, but the law says about a period of 6 to 12 months, but at least 1 time per year. However, some devices require inspection at least once every 6 months.
The period for inspection of equipment may be established by local structures of the metrological service. Employees of the Centers of Standardization and Metrology sometimes abuse their position and increase the frequency of examinations. The FMC can establish a six-month verification period without significant reasons.
Calibration is also distinguished - a set of measures for gas analyzers that are used outside the field of state regulation. The interval between calibrations is not clearly set. At the same time, the methodology sometimes indicates technically sound recommendations regarding the timing for the next such procedure.
What is the essence of the verification work methodology?
The verification procedure is a document with detailed operations to confirm the suitability of the gas analyzer.For different brands and models, the approach is different.
Excerpt from the methodology for gas analyzers of the models 1800, 1900, 2200, 5100, 5200 of the company Servomex Group Limited: the first item - verification operations
The document usually includes 7 points:
- Verification operations. We are talking about the main indicators, including errors.
- Facilities. These include instruments and gas mixtures for testing and determining metrological characteristics.
- Safety requirements.
- Conditions for holding.
- Training.
- Holding.
- Presentation of verification results. At this stage, the believer draws up a protocol and issues a document-certificate.
Direct verification begins with the fact that they connect a cylinder with span gas to the control valve. Then the rotameter is brought to the exit. The latter is attached with an adapter for calibration work. The mixture is then allowed to enter the gas analyzer, and when the instrument gives evidence, they are fixed.
The specialist will calculate the error and determine the time taken to establish the testimony. The believer will compare the indicators with the standards and draw up the results.
Overview of a domestic gas analyzer, connection, operating principle, testing:
Verification of gas analyzers and gas detectors using modern equipment:
Verifications themselves will not cause organizational difficulties, especially if security issues have been given due attention. A device for determining the composition of the gas is considered valid after the main and absolute errors are acceptable. It is possible that the timing for calibration of the gas analyzer will become a problem. The consumer should seek a one-year interval instead of an unreasonably short period. An unsatisfactory metrological result can also be challenged.
Leave your comments, ask questions about the topic of the article, share experiences and share useful information. The contact form is located under the article.